The Pmise fractional CO2 laser vaginal machine is a non-surgical 10600nm system that rebuilds collagen in the vaginal walls, contracts existing tissue and enhances the sensitivity of vaginal receptors. It restores tightness and elasticity lost through childbirth or aging, improving comfort and sexual satisfaction without incisions, and also supports vaginal health care.
Pmise-C01 / Pmise-C02 / Pmise-C04
A CO2 laser vaginal tightening machine is a non-surgical vaginal rejuvenation system that delivers 10600nm fractional laser energy to the vaginal mucosa through a dedicated gynecological applicator. It is designed for gynecology clinics, medical spas and aesthetic centers that want to treat postpartum laxity, age-related dryness and reduced sensitivity without incisions or a surgical theatre. The core technology is an RF-excited fractional CO2 laser whose controlled thermal effect contracts existing tissue immediately and stimulates fibrocyte activity and new collagen over the following weeks. The typical outcome is progressively restored tightness, elasticity and comfort, with the same platform also available for facial skin resurfacing.
Vaginal CO2 laser tightening works by delivering 10600nm fractional laser energy directly to the vaginal mucosa and muscular tissue, where it is strongly absorbed by water - the main component of the tissue - and converted into a controlled thermal effect. This extensive, regular heating gives an instant tightening and lifting result, while a large number of extremely tiny micro-ablative (peeling) points are created at the same time.
These micro points stimulate massive fibrocyte regeneration and collagen remodeling in the vaginal walls, which gradually restores lasting elasticity and tightens the vagina over the weeks following treatment - the same collagen-rebuilding mechanism used by our fractional CO2 laser machine for skin resurfacing. The patented comfort technology keeps the procedure non-invasive and safe, so doctors and patients can choose it instead of a surgical method. Resurfacing the vaginal mucosa also supports routine feminine health care and helps reduce the risk proportion of chronic disease.
For non-invasive tightening of facial and body skin without a laser, you can also compare this system with our HIFU face lifting and skin tightening machine.
Clinics evaluating vaginal rejuvenation equipment usually weigh the laser approach against referring patients for surgery. The comparison below is qualitative and focuses on how each option fits an aesthetic practice.
| Technology | Best for | Depth / wavelength | Downtime | Suitable buyer |
| Fractional CO2 vaginal laser (this machine) | Postpartum laxity, age-related dryness and reduced sensitivity, routine vaginal health care | 10600nm micro-ablative points in the mucosa; energy, spot density and pulse mode fully adjustable | Non-invasive, no incisions; surrounding tissue supports rapid healing | Gynecology clinics, medical spas and aesthetic centers offering non-surgical vaginal rejuvenation |
| Surgical vaginoplasty | Structural repair cases that require surgical correction | — | Surgical procedure with incisions and a hospital recovery period | Hospitals and surgical centers with an operating theatre and surgeons |
| Pmise-C01 | Pmise-C02 | Pmise-C04 | |
| Laser Type | RF-excited ion laser | RF-excited ion laser | RF-excited ion laser |
| Wave Length | 10600nm | 10600nm | 10600nm |
| Power | <=30W | <=40W | <=75W |
| Operating Mode | CW | CW | CW |
| Output Mode | CW, Ultra pulse, Interval pulse | CW, Ultra pulse, Interval pulse | CW, Ultra pulse, Interval pulse |
| Spot Size Mode | Single | Single | Single |
| Pulse Energy | 8.3mJ-166mJ | 8.3mJ-166mJ | 8.3mJ-166mJ |
| Diameter of Focal Spot | 100um-2000um | 100um-2000um | 100um-2000um |
| Pulse Width | 0.1005ms-10.05ms | 0.1005ms-10.05ms | 0.1005ms-10.05ms |
| Scan Graphics | Triangle/square/rectangle/diamond | Triangle/square/rectangle/diamond | Triangle/square/rectangle/diamond |
| Scanning Mode | Randomized scanning | Randomized scanning | Randomized scanning |
| Aiming Power | <=5mW | <=5mW | <=5mW |
| Beam Transport Device | Imported Korea 7 Joint Arm | Imported Korea 7 Joint Arm | Imported Korea 7 Joint Arm |
| Aiming Wave Length | 635 nm | 635 nm | 635 nm |
| Number of Focal Spot | (Square)36(6*6)144(12*12) | (Square)36(6*6)144(12*12) | (Square)36(6*6)144(12*12) |
| 576(24*24) (/cm2) | 576(24*24) (/cm2) | 576(24*24) (/cm2) | |
| ≈6.25% (144/cm2) ≈25% (576/cm2) | ≈6.25% (144/cm2) ≈25% (576/cm2) | ≈6.25% (144/cm2) ≈25% (576/cm2) | |
| Area Calculation | 1cm*1cm 2cm*2cm 3cm*3cm | 1cm*1cm 2cm*2cm 3cm*3cm | 1cm*1cm 2cm*2cm 3cm*3cm |
| Pulse Duration | 1ms-100ms | 1ms-100ms | 1ms-100ms |
| Power Supply | AC 220V±10%, 50Hz | AC 220V±10%, 50Hz | AC 220V±10%, 50Hz |
| Cooling System | Air Cooling | Air Cooling | Air Cooling |
| Insurance Standard | Max 10A | Max 10A | Max 10A |
| Input Power | 600W | 600W | 600W |
Get factory price and full technical specifications for Pmise-C01 / C02 / C04 ›
Whichever profile fits you, the machine must be operated by trained professionals, and patient suitability should always be confirmed by a physician.
It is a non-surgical device that delivers 10600nm fractional CO2 laser energy to the vaginal mucosa through a dedicated applicator. The controlled thermal effect stimulates fibrocyte activity and new collagen formation in the vaginal walls, contracting existing tissue to restore tightness, elasticity and comfort without surgery.
The 10600nm laser is strongly absorbed by water in the vaginal mucosa, producing a regular thermal effect plus a large number of extremely tiny micro-ablative points. These points stimulate massive fibrocyte regeneration and collagen remodeling, so the vaginal wall gradually tightens: an instant tightening and lifting effect appears first, followed by progressive improvement as new collagen forms.
Typical candidates are women with vaginal relaxation after childbirth, reduced tightness and sensitivity that comes with age, vaginal dryness or discomfort around menopause, or hygiene-related concerns such as vaginitis. It offers a non-invasive alternative for women who want to improve vaginal tightness and health without surgery; suitability should always be confirmed by a physician.
The treatment is non-invasive: the applicator delivers fractional laser energy with comfort-oriented technology, and energy, spot density and pulse mode are fully adjustable, so treatment intensity can be kept mild. Because only micro-points of mucosa are treated, the surrounding tissue supports rapid healing. As with any medical procedure, it must be performed by trained professionals.
Pricing depends on the laser power and configuration you choose. The Pmise vaginal series is built on the C01, C02 and C04 platforms with maximum output of 30W, 40W and 75W respectively, supplied with the vaginal treatment applicator. Send your requirements via the contact form below to receive a detailed, factory-direct quotation.
The vaginal tightening machine is covered by a one-year warranty from the date you sign for the goods, plus lifetime maintenance. Pmise's service team of 50+ experts and 100+ technicians responds to technical consulting within 30 minutes, and door-to-door service is arranged at least twice a year.
All three platforms drive the same vaginal applicator and share identical pulse energy, focal spot range and output modes, so they differ only in maximum power: 30W, 40W and 75W. Tell us your expected patient volume and whether you also plan facial resurfacing, and we will send model suggestions and a factory quotation within 12-24 hours.
Treatment results vary by skin type, indication and operator settings. Professional operator training is required before clinical use.
Every Pmise machine is verified through rigorous testing. Tell us your target treatments and market.